Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13543369

- Product Categories
- Friendly Links
- home > Supply > Fiberglass tanks installed programs _ the best quality of domestic water tank manufacturers
Information Name: | Fiberglass tanks installed programs _ the best quality of domestic water tank manufacturers |
Published: | 2014-09-11 |
Validity: | 30 |
Specifications: | 1000 * 1000mm; 1000 * 500mm; 500 * 500mm |
Quantity: | 1111.00 |
Price Description: | |
Detailed Product Description: | Fiberglass tanks fiberglass tanks installation program describes the installation program is assembled panels made by SMC molded tank. Due to the use of food-grade resin, water quality is good, clean and non-polluting, high strength, light weight, corrosion resistance, appearance, long life, easy maintenance and management features. I produced fiberglass tanks installed program is the National Bureau of Building Materials Industry and the Ministry of Construction [1999] No. 330 recommended products group, in full compliance with State Bureau of Building Standards JC658.1-2003 technical performance requirements. The water tank is detected by the national authorities, the tank meets "drinking water transmission and distribution equipment and safety evaluation of protective material specification" requirement, the water quality in line with the national "drinking water standards." Follow the principles offer fiberglass tanks installed programs that you are used to hold drinking water? Or industrial water? If you want to install drinking water, it is recommended to use food-grade fiberglass resin. Because food-grade fiberglass resin is non-toxic tasteless. Slightly higher price. If it is used to hold water for industrial use, then it is recommended to choose industrial-type fiberglass resin, the price is slightly lower. Because different media to be stored, so the final choice of material is different, the price is also different. Fiberglass tanks installed programs which contain fiberglass tanks installed accessories program in addition to the tank plate, but also includes a lot of accessories, including: the base channel, external ladders, internal ladders, fixed angle iron, auxiliary angle iron, tape, stretch, support, external reinforcement plate, the reinforcement plate on the wire, flanges, manholes, fiberglass water tank level gauge flanged installation program to determine the location of the principles of a) into the water tank into the water usually access from the side wall can also be from the bottom or top access. When using the pipe network pressure water tank, which should be located at the outlet of the inlet pipe network or hydraulic valve float. Float valve is usually less than 2. Float network diameter inlet pipe diameter as the float valve should be fitted before each valve repair (2) outlet: tank outlet pipe can be accessed from the wall or bottom of the cases. Pick out from the side wall outlet or from the bottom outlet port connected to the top surface of the bottom of the time, should be above the tank bottom 50 mm. Yan outlet port should be set brake tank into the outlet pipe should leave settings, when into the outlet pipe when the pipe is the same, check valves should be installed in the outlet pipe. When the demand for the installation of backstop together, should adopt less resistance swing check valve replacement lift and elevation of the tank should be less than 1m above the minimum level. Day in combination with a water tank fire when fire-return Yan outlet should be lower than the day on the water siphon tube top (below the top of the pipe, the days of vacuum siphon is damaged, there is only sure fire outlet pipe water out) at least 2m, it has a certain pressure propulsion valve. When the fire attack, fire caliber real role to play reserve water (3) an overflow pipe: FRP tank overflow pipe installation program can be accessed from the side or bottom, its diameter blood flow by excretion into the tank to determine the maximum and cheaper than No one big l inlet pipe 2. Shall install a valve on the overflow pipe. Overflow pipe shall not directly interface with the drainage system, it is necessary to choose a direct drain, are dust, insects, mosquitoes and other ways to enter the overflow pipe should be anti-such as setting seal, filters and so on. (4) the sewage outfall: FRP tank installation program, also known as Epsom outfall outlet, usually open in the bottom of the tank for cleaning the tank drainage. How to calculate the volume of fire water tank FRP fiberglass tanks for the storage of fire extinguish the initial fire water, fire protection design specification clearly states as follows: "architectural design code for fire protection," Section 8.6.3 states: indoor fire water tanks (including tank zoning district water supply system) 10min fire water should be stored, when the indoor fire water no more than 25L / s, the calculated water storage tank fire over 12m3, still using 12m3; When indoor fire water than 25L / s, calculated over water storage tank fire 18m3, still using 18m3. "Fire protection design of tall buildings" section 7.4.7.1 states: high fire fire water storage tank, a class of public buildings should not be less than 18m3; II a class of public buildings and residential buildings should not be less than 12m3; types of residential buildings not less than 6.00m3. Section 7.4.7.3 states: parallel manner divisional fire water tank capacity and high fire water tank same. In addition, the combination of water and other fiberglass tanks installed program volume, in addition to meeting its own fire water reserve, we must also meet other water reserve. Tang Jia fiberglass tanks installed programs advantage Tang Jia tank "in good faith as a fundamental, customer-focused, quality of survival, innovation and development", follow the modern philosophy, the scale has grown in strength, production capacity and improving. Tang Jia founded a strong technical force, high-quality team unity and hard work, the company products are exported to Southeast Asia and Europe and other countries in recent years, our company produces fiberglass tanks installed programs sold throughout the country, the products have been subject to domestic and foreign customers to praise, quality trusted by the user. |
Admin>>>
You are the 4095 visitor
Copyright © GuangDong ICP No. 10089450, Tang Jia tank Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 4095 visitor
Copyright © GuangDong ICP No. 10089450, Tang Jia tank Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility